Blower Utilization 20KW 24000RPM Higher Velocity Synchronous Long lasting Magnet Motor
Item Function
1.Suited for the 24000rpm rated pace
two.Higher energy & higher torque
three.High effectiveness
four.Tiny dimensions
five.Low sounds reduced vibration
6.Patented cooling composition
seven.Straightforward routine maintenance and extended daily life time
8.Tough, dependable
Requirements
Product sort: SRPM112H4O20
Voltage: 380V AC
Rated Energy: 20KW
Rate Torque : 8N.m
Rated Speed: 24000rpm
Isolation: H
N Fat: about 20KG
Cooling Technique: oil cooling
Rated Frequency:800HZ
Pole:4
Software
Substantial-pace Compressors,Enthusiasts,Pumps,Air Knife
Other motors you will be interested in
Motor type | Voltage (V AC) |
Rated power (kW) |
Rated torque (N.m) | Rated pace (rpm) |
Performance (%) |
Services Factor | Insulation | Ingress protection | Pole Amount | Weight (kg) |
Cooling Approach | Place Signal | Installation Technique |
SRPM151M8XW11 | 380 | eleven | eleven | 9600 | ninety six | S1 | H/F | IP67 | 8 | ten | Oil circulation | Resolver | B35 |
SRPM205M8XO45 | 380 | 45 | 36 | 12000 | 96.3 | S1 | H/F | IP67 | eight | 35 | Oil circulation | Resolver | B35 |
SRPM205M8XO55 | 380 | fifty five | forty three.8 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 38 | Oil circulation | Resolver | B35 |
SRPM205M8XO75 | 380 | 75 | fifty nine.seven | 12000 | ninety six.five | S1 | H/F | IP67 | eight | forty three | Oil circulation | Resolver | B35 |
SRPM205M8XO90 | 380 | ninety | 71.6 | 12000 | ninety six.five | S1 | H/F | IP67 | 8 | forty seven | Oil circulation | Resolver | B35 |
SRPM205M8XO110 | 380 | a hundred and ten | 87.6 | 12000 | ninety six.five | S1 | H/F | IP67 | eight | seventy five | Oil circulation | Resolver | B35 |
SRPM205M8XO132 | 380 | 132 | one hundred and five | 12000 | ninety six.5 | S1 | H/F | IP67 | 8 | eighty | Oil circulation | Resolver | B35 |
SRPM205M8XO160 | 380 | a hundred and sixty | 127.three | 12000 | ninety six.5 | S1 | H/F | IP67 | eight | 87 | Oil circulation | Resolver | B35 |
SRPM205M8XO185 | 380 | 185 | 147.2 | 12000 | 96.five | S1 | H/F | IP67 | 8 | ninety five | Oil circulation | Resolver | B35 |
FAQ
one. Can performanent magnet synchronous motor be utilized as generator?
No. Everlasting magnet synchronous motor is absolutely diverse from generator. It is only ac motor that outputs pace and torque to travel electrical devices, but not electrical power supply.
2. Why can not straight use 3 stage ac offer voltage to begin long term magnet synchronous motor?
Becuase rotor is with large innertia, and magetic documents spins so fast that static rotor has no way to spin with magetic filed.
3. Any unique technological ask for on this motor’s VFD driver? And Do you have such driver?
Permanent magnet synchronous motor’s driver ought to be vector manage VFD with unique internal software program, this kind of as Siemens 6SE70 sequence, Yakawa CR5 sequence, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, and many others.. Indeed, our MH300 sequence VFD matches with this motor.
4. Is there any protecting actions to protect long lasting magnet rotor from failure?
Indeed, every single long term magnet rotor passes corrossion resistance, consistency, large temperature demagnetization check, linear demagnetization examination, and so forth. Its demagnetization index is inside 2%. But if functioning setting is severe oxiditive corrosion, kindly advise for greater defense level.
five. The place is this everlasting magnet synchronous motor typically used to?
This long lasting magnet synchronous motor is typically utilized to variable frequency velocity scenario.